MU1000K, Universal Measuring Transducer, for Pt 100 (RTD) and standard signals

Ready to ship today,
Delivery time appr. 1-3 workdays
- Part number: T236002.1
Universal-Measuring-Transducer for Temperature Pt100, DC Current and Voltage, Isolating Amplifier
Universal-measuring-transducers MU1000K can measure signals Pt100 (RTD) and DC current (0/4-20 mA) and voltage (DC 0/2-10 V). Several measuring-ranges are pre-programmed. More can be easily scaled. Temperatures at sensors Pt 100 can be evaluated from -200 °C to + 800 °.
The output-signals 0/2-10 V and 0/4-20 mA are potentially separated from inputs and supply voltage. With its universal power-supply AC/DC 24-240 V the measuring transducer can be connected to all common supply-voltages.
Overview of functions
- Current input 0-20mA, scalable
- Voltage input 0-10V, scalable
- Input Pt 100, 3-wire, -200…+800 °C, scalable
- Output signal 0-20mA and 0-10V or 4-20mA and 2-10V
- Rated Supply Voltage AC/DC 24-240V
- Insulation between inputs, outputs and supply voltage
- Standard ranges adjustable, universally scalable input ranges
Technical data
Rated supply voltage Us
.......
AC/DC 24 – 240 V 0/50/60 Hz < 3 W < 5 VA
Tolerance
.......
DC 20,4 - 297 V
AC 20 - 264 Vv
Pt100 sensor input
Measuring range
.......
-200 °C .. 800 °C
Tolerance
.......
±0,5 % of measured value ±0,5 K
Resolution
.......
≤0,6 mA
Sensor current
.......
≤ 0,5% vom Endwert
Temperature factor
.......
<0,04 °C / K
Output (2 outputs with common ground)
Voltage output
.......
DC 0/2 – 10 V
Tolerance
.......
0,3 % of full scale (from 0,1 V)
Temperature factor
.......
< 0,01 % / K
Current output
.......
DC 0/4 – 20 mA
Tolerance
.......
0,3 % of full scale (from 0,1 mA)
Temperature factor
.......
< 0,015 % / K
Resolution
.......
11,6 Bit < 6,1 μA
Load
.......
≤ 500 Ω
Error from load
.......
(250 Ω – resistance) / 250 Ω * 0,3 % of final value
Test conditions (EN 61010-1)
Rated impulse voltage
.......
4000 V
Contamination level
.......
2
Rated insulation voltage Ui
.......
250 V
Galvanic insulation / Test-voltage
.......
Us output ...... DC 3540 V
Us input ...... DC 3540 V
input output ...... DC 3540 V
On-time
.......
100 %
Permitted ambient air temperature
.......
-20 °C ... +65 °C
EN 60068-2-2 dry heat
Interference resistance
.......
EN 61000-6-2
Interference transmission
.......
EN 61000-6-3
Vibration resistance EN 60068-2-6
.......
2…25 Hz ±1,6 mm
25 ... 150 Hz 5 g
Housing
Housing
.......
Type K
Dimension (H x W x D)
.......
75 x 22,5 x 110 mm
Line connection solid wire
.......
each 1 x 0,5…2,5 mm2
Stranded wire with insulated ferrules
.......
each 1 x 0,14…1,5 mm2
Torque
.......
0.5 Nm (3,6 lb.in)
Protection class housing
.......
IP 40
Protection class terminals
.......
IP 20
Mounting
.......
Snap mounting on 35 mm standard rail EN 60 715 or M4 screws
Weight
.......
app. 100 g
Input / measuered parameter: | Measuring Input Pt 100 (RTD), Standard signals 0/4-20 mA, 0-10 V, Current measuring |
Outputs: | Analog output 0/4-20mA, 0-10V |
Design: | Mount in switchgear cabinet |
Approvals: | UKCA, UL/CSA |