STW168M, Control for suction plant Bus-module for valves, DC 24 V

STW168M_neu_Produktfoto.png
Price after registration.

Ready to ship today,
Delivery time appr. 1-3 workdays

  • S225544
STW168M, Control for suction plant Bus-module for valves, DC 24 V 8-channel bus-module... more

Bus module for controlling up to 8 sliders in extraction systems

 

Bus module for controlling sliders in extraction systems

Technical Data

Rated supply

Rated supply voltage Us

.......

DC 24 V, SELV, PELV

 

Tolerance

.......

DC 20 - 30 V

 

Power consumption

.......

< 3,5 W

 

Imax Bus line

.......

< 10 A

 

Switch on time

.......

100 %

 

Relay output K0...K7

.......

8 x 1 Wechsler, gemeinsame Wurzel

 

Switching voltage

.......

max. AC 300 V; DC 300 V

 

Switch on current closer (NO)

.......

AC 15 A 4 s 10 % ED

 

Minimum voltage/current

.......

12 V 10 mA

 

Conventional thermal current Ith

.......

max. 5 A

 

Total current on terminal 05

.......

max. 5 A

 

Switching capacity max. AC cos phi = 1

.......

1500 VA

 

Inputs I0...I7

.......

Current transformer STWA1(H), potential free contacts or Current sensor type S1

 

Internal resistant

.......

approx. 15 kOhm

 

Overload with STWA1(H)

.......

max. 100 A continuous, max. 300 A  10 s

 

Installation conditions

permissible ambient temperature

.......

-20°C…+55°C

 

permissible storage temperature

.......

-20°C…+70°C

 

Mounting

.......

< 2000 m see level

 

Climatic conditions

.......

5 - 85 % rel. F., no condensation

 

Shaking safety EN 60068-2-6

.......

2...13,2 Hz +/- 1 mm  13,2...100 Hz 1 g

 

Housing

Housing / Installation Frame

.......

Design V6 / Front counting kit ER6, 6 TE

 

Mounting height

.......

58 mm

 

Dimensions (w x h x d) mm

.......

105 x 90 x 58 mm

 

Cable connection solid

.......

1 x 0,34 - 2,5 mm2 / AWG 22-12

 

Finely stranded with end sleeve

.......

1 x 0,34 - 2,5 mm2 / AWG 22-12

 

Stripping length / torgue

.......

8 mm / 0,5 Nm

 

Attachment

.......

Snap on mounting on standard rail 35 mm according to EN 60 715 or screws M4 (additional bolts are not included)

 

Protection housing / terminals

.......

IP 30 / IP 20

 

Weight

.......

approx. 250 g

 
Design: Mount in switchgear cabinet, Mount in circuit breaker box, Panel mount
Applications: Controils for suction plants